Applications: Active control of vibration on medical robots – High frequency shakers – Fretting fatigue testing – Space qualified positioner
| Blocked Force | 780 N |
|---|---|
| Capacitance | 13 µF |
| Nominal Stroke | 220 µm |
| Stiffness | 3,6 N/µm |
| Resonance frequency | 1015 Hz |
| Available options | Strain gauge, Vacuum Compatibility |
| Status | Standard |
| Blocked Force | 2100 N |
|---|---|
| Capacitance | 13 µF |
| Nominal Stroke | 99 µm |
| Stiffness | 21 N/µm |
| Resonance frequency | 2090 Hz |
| Available options | Strain gauge, Vacuum Compatibility |
| Status | Standard |
| Blocked Force | 1500 N |
|---|---|
| Capacitance | 13 µF |
| Nominal Stroke | 120 µm |
| Stiffness | 12 N/µm |
| Resonance frequency | 1880 Hz |
| Available options | Strain gauge, Vacuum Compatibility |
| Status | Standard |
| Blocked Force | 3300 N |
|---|---|
| Capacitance | 13 µF |
| Nominal Stroke | 65 µm |
| Stiffness | 51 N/µm |
| Resonance frequency | 2555 Hz |
| Available options | Strain gauge, Vacuum Compatibility |
| Status | Standard |
| Blocked Force | 540 N |
|---|---|
| Capacitance | 13 µF |
| Nominal Stroke | 300 µm |
| Stiffness | 1,8 N/µm |
| Resonance frequency | 758 Hz |
| Available options | Strain gauge, Vacuum Compatibility |
| Status | Standard |